Fault Possible cause Remedial action
Temperature display
indicates “E..”.
Electronics have detected
a fault.
Call customer service.
Appliance is not cooling,
temperature display and light
are lit.
Showroom mode is
switched on.
Hold down alarm button, Fig "/5, for
10 seconds until an acknowledgement signal
sounds.
After a short time check whether your
appliance is cooling.
The light does not function. The LED light is defective. See chapter “Light (LED)” section.
Appliance was open too
long.
Light is switched off after
approx. 10 min.
When the appliance is closed and opened,
the light is on again.
The “cool-fresh”
compartment is too warm or
too cold.
The standard setting has
been set too high or too low
(e.g. if there is frost
in the “cool-fresh”
compartment).
The temperature in the “cool-fresh”
compartment can be set to be 3 steps warmer
and/or colder, Fig. ". If the temperature in the
refrigerator compartment is set to 0, the
temperature in the “cool-fresh” compartment
is almost 0 °C.
Note
A change to the standard setting will affect the
temperature in the refrigerator compartment
and freezer compartment.
1. Hold down “super” button 2 for 3 seconds
until temperature display 4 flashes.
2. Change the setting using the temperature
setting button 3.
Setting -3 corresponds to the coldest
setting
Setting +3 corresponds to the warmest
setting
The selected setting is saved after one
minute.