Fault Possible cause Remedial action
The side panels of the
appliance are warm.
Pipes run into the side panels
which heat during the
cooling process.
That is normal behaviour for the appliance and
not a fault.
Furniture touching the appliance will not be
damaged by the heat.
Displays do not illuminate. Power failure; the fuse has
been switched off; the mains
plug has not been inserted
properly.
Connect mains plug. Check whether the power
is on, check the fuses.
Freezer compartment door
was open for a long time;
temperature is no longer
reached.
The evaporator (refrigeration
generator) in the
NoFrost system is covered
in thick ice and can no
longer be defrosted fully
automatically.
To defrost the evaporator, remove the frozen
food with the compartments, insulate well
and store in a cool location.
Switch off the appliance and move it away
from the wall. Leave the appliance door open.
After approx. 20 min. the condensation begins
to run into the evaporation pan,
at the rear of the appliance.
To prevent the evaporation pan
from overflowing in this case,
mop up the condensation with a sponge.
The evaporator is defrosted when the water
stops running into the evaporation pan. Clean
the interior. Switch the appliance
back on again.
The photos are blurry. The door was closed too
quickly.
Close the door more slowly.
The anti-mist film is
damaged.
Replace the anti-mist film.
The following settings are
switched off:
Audible signals
Interior lighting
Messages on the display
panel
Automatic super freezing
The background illumination
of the display panel is
reduced.
Buttons are locked.
sabbath mode is switched
on.
Press super button for 15 seconds.