LMVSeriesTechnicalInstructions
DocumentNo.LV51000
SCCInc. Page1 Section7
71:TroubleshootingIntroduction
TheLMV5hasanextensivelistoffaultcodestohelpclarifythenatureofanyfault.Section73
describeswhateveryfaultcodeisandgivessomeguidanceonhowtocorrectit.
ThemostcommonissuesseenontheLMV5aredescribedingreaterdetailinSection72to
offeradditionaltroubleshootinghelp.TheissuescoveredinSection72are:
General
CANbusFaultsIncludingAZLnotonBusandSystemTest.......................................................2
FaultPositioningActuatorErrorCode15....................................................................................6
InternalFaultActuatorErrorCode19.........................................................................................7
FlameFailureErrorCode25or26...............................................................................................8
OpenCircuit/ShortCircuitSensorFaultsErrorCodeA6(Diagnostics50…5A)..........................9
OpenSafetyLoopErrorCode21...............................................................................................10
LMV5WillNotStart(StaysinPhase12).......................................................................................11
LMV5WillNotModulateProperly...............................................................................................12
O2Trim
O
2
SensorisNotReading..............................................................................................................13
O
2
SensorReadingGrosslyHighorLow........................................................................................14
O
2
SensorReadsButRespondsVerySlowly.................................................................................14
AmbientorStackTemperatureSensorReadingIncorrectly........................................................15
AZLsaysO2ModulenotactiveornotAvailable.......................................................................15
AZLSaysO2Setpointmustlie0.1%belowO2RatioControl”or“O2Setpointmustlie0.1%
aboveO2Min........................................................................................................................16
AZLSaysMeasurementnotSuccessfulWhenMeasuringtheDelayTimeforO
2
Trim.............17
AZLSaysO2TrimControlAutomaticallyDeactivated...............................................................18
VariableSpeedDrive(VSD)
VSDWillNotOperate....................................................................................................................19
UnsuccessfulVSDStandardization...............................................................................................20
AZLSaysFanSpeedNotReachedorControlRangeLimitationVSDModule........................22