NCK alarms
03/2009 Overview of Alarms
2-29
© Siemens AG, 2009. All Rights Reserved
SINUMERIK 840D sl, 840Di sl, SINAMICS, Diagnostics Manual (DAsl), 03/2009
4026 Machine data %1[%2], link axis NC%3_AX%4 not used by any channel
Parameters: %1 = String: MD identifier
%2 = Index: MD array
%3 = NCU number
%4 = Machine axis number
Definitions: The link axis is not referenced by any channel.
Reaction: NC not ready.
NC Start disable in this channel.
Interface signals are set.
Alarm display.
NC Stop on alarm.
Remedy: Correct and complete the logical axis assignments. Check machine data MD20070
$MC_AXCONF_MACHAX_USED and MD10002 $MN_AXCONF_LOGIC_MACHAX_TAB.
Program Con-
tinuation:
Switch control OFF - ON.
4027 NOTICE! MD %1 was also changed for the other axes of axis container
%2
Parameters: %1 = String: MD identifier
%2 = Axis container number
Definitions: Message to the user indicating that the machine data change for the axis was also performed for all
other axes in the same container.
Reaction: Alarm display.
Remedy: None
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
4028 Attention! The axial MDs of the axes of the axis containers were
matched.
Definitions: Note for the user, that the machine data of the axis were matched in the axis containers.
Reaction: Alarm display.
Remedy: None
Program Con-
tinuation:
Clear alarm with the RESET key. Restart part program
4029 NOTICE! The axial MDs in axis container %1 will be matched on the next
power-up
Parameters: %1 = Axis container number
Definitions: Message to the user indicating that the machine data of the axes in the axis container will be matched
on the next power-up. An axis container allows axes to be exchanged between channels and NCUs.
To ensure that no conflicts arise, the axes within the same axis container must have a similar behavior.
The first axis in the axis container determines which machine data have to be the same for the other
axis in the axis container.
Reaction: Alarm display.
Remedy: None
Program Con-
tinuation:
Clear alarm with the Delete key or NC START.
4030 [Channel %1: ] Identifier missing in machine date %2[%3]
Parameters: %1 = Channel number
%2 = String: MD identifier
%3 = Index: MD array index
Definitions: An axis identifier is expected for the displayed MD in accordance with the axis configuration in the
MD20070 $MC_AXCONF_MACHAX_USED and MD20050 $MC_AXCONF_GEOAX_ASSIGN_TAB.