5 System Parameters International English
MICROMASTER 440 Operating instructions
64 6SE6400-5CA00-0BP0
Alarms, Warnings and Monitoring (P0004 = 21)
Par. No. Parametername Default Acc WS QC
r0947[8] Last fault code - 2 - -
r0948[12] Fault time - 3 - -
P0952 Total number of faults 0 3 CT N
P2100[3] Alarm number selection 0 3 CT N
P2101[3] Stop reaction value 0 3 CT N
r2110[4] Warning number - 2 - -
P2111 Total number of warnings 0 3 CT N
r2114[2] Run time counter - 3 - -
P2115[3] AOP real time clock 0 3 CT N
P2150[3] Hysteresis frequency f_hys 3.00 3 CUT N
P2151[3] CI: Monitoring speed setpoint 0:0 3 CUT N
P2152[3] CI: Act. monitoring speed 0:0 3 CUT N
P2153[3] Time-constant speed filter 5 2 CUT N
P2155[3] Threshold frequency f_1 30.00 3 CUT N
P2156[3] Delay time of threshold freq f_1 10 3 CUT N
P2157[3] Threshold frequency f_2 30.00 2 CUT N
P2158[3] Delay time of threshold freq f_2 10 2 CUT N
P2159[3] Threshold frequency f_3 30.00 2 CUT N
P2160[3] Delay time of threshold freq f_3 10 2 CUT N
P2161[3] Min. threshold for freq. setp. 3.00 2 CUT N
P2162[3] Hysteresis freq. for overspeed 20.00 2 CUT N
P2163[3] Entry freq. for perm. deviation 3.00 2 CUT N
P2164[3] Hysteresis frequency deviation 3.00 3 CUT N
P2165[3] Delay time permitted deviation 10 2 CUT N
P2166[3] Delay time ramp up completed 10 2 CUT N
P2167[3] Switch-off frequency f_off 1.00 3 CUT N
P2168[3] Delay time T_off 10 3 CUT N
r2169 CO: Act. filtered frequency - 2 - -
P2170[3] Threshold current I_thresh 100.0 3 CUT N
P2171[3] Delay time current 10 3 CUT N
P2172[3] Threshold DC-link voltage 800 3 CUT N
P2173[3] Delay time DC-link voltage 10 3 CUT N
P2174[3] Torque threshold T_thresh 5.13 2 CUT N
P2176[3] Delay time for torque threshold 10 2 CUT N
P2177[3] Delay time for motor is blocked 10 2 CUT N
P2178[3] Delay time for motor is stalled 10 2 CUT N
P2179 Current limit for no load ident. 3.0 3 CUT N
P2180 Delay time for no load ident. 2000 3 CUT N
P2181[3] Belt failure detection mode 0 2 CT N
P2182[3] Belt threshold frequency 1 5.00 3 CUT N
P2183[3] Belt threshold frequency 2 30.00 2 CUT N
P2184[3] Belt threshold frequency 3 50.00 2 CUT N
P2185[3] Upper torque threshold 1 99999.0 2 CUT N
P2186[3] Lower torque threshold 1 0.0 2 CUT N