Issue 01/06 Parameter Description
MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0
119
P1027[3] Fixed frequency mode - Bit 5 Min: 1
CStat: CT Datatype: U16 Unit: - Def: 1
P-Group: SETPOINT Active: first confirm QuickComm.: No Max: 2
direct selection or direct selection + ON for bit 5
Possible Settings:
1 Direct selection
2 Direct selection + ON command
Index:
P1027[0] : 1st. Command data set (CDS)
P1027[1] : 2nd. Command data set (CDS)
P1027[2] : 3rd. Command data set (CDS)
Details:
See parameter P1001 for description of how to use fixed frequencies.
P1028[3] BI: Fixed freq. selection Bit 5 Min: 0:0
CStat: CT Datatype: U32 Unit: - Def: 722:5
P-Group: COMMANDS Active: first confirm QuickComm.: No Max: 4000:0
Defines origin of fixed frequency selection.
Index:
P1028[0] : 1st. Command data set (CDS)
P1028[1] : 2nd. Command data set (CDS)
P1028[2] : 3rd. Command data set (CDS)
Dependency:
Accessible only if P0701 - P0706 = 99 (function of digital inputs = BICO).
Details:
See P1020 (fixed frequency selection Bit 0) for most common settings.
Level
3
Level
3