EasyManua.ls Logo

Siemens MICROMASTER 440 - VDC Controller; Configuration of VDC Controller

Siemens MICROMASTER 440
328 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter Description Issue 01/06
MICROMASTER 440 Parameter List
148 6SE6400-5BB00-0BP0
t
V
DC
t
V
DC, Chopper
V
DC, act
Chopper
active
t
t
Chopper , ON
Chopper
t
f
1
=
Chopper
Hz 2000
1
=
t
t
Chopper , ON
t
100
x
â‹…=
Chopper
V
DC, act
–
V
DC, Chopper
100 %
V
∆V
0
1
1
0
x
Alarm
A0535
Duty cycle
monitoring
0
1
P1237
Mains
200 - 240 V
9.8 V
∆
V
380 - 480 V
17.0 V
500 - 600 V
21.3 V
The threshold for the warning A0535 is equivalent to 10 seconds running at 95 % duty cycle. The duty cycle
will be limited when it was running 12 seconds at 95 % duty cycle.
3.28 Vdc controller
P1240[3] Configuration of Vdc controller Min: 0
CStat: CT Datatype: U16 Unit: - Def: 1
P-Group: FUNC Active: Immediately QuickComm.: No Max: 3
Enables / disables Vdc controller.
The Vdc controller dynamically controls the DC link voltage to prevent overvoltage trips on high inertia
systems.
Possible Settings:
0 Vdc controller disabled
1 Vdc-max controller enabled
2 Kinetic buffering (Vdc-min controller) enabled
3 Vdc-max controller and kinetic buffering (KIB) enabled
Index:
P1240[0] : 1st. Drive data set (DDS)
P1240[1] : 2nd. Drive data set (DDS)
P1240[2] : 3rd. Drive data set (DDS)
Level
3
www . ElectricalPartManuals . com

Table of Contents

Other manuals for Siemens MICROMASTER 440

Related product manuals