Parameters Issue 01/06
MICROMASTER 440 Parameter List
20 6SE6400-5BB00-0BP0
ParNo Parameter text
P1580[3] Efficiency optimization
P1582[3] Smooth time for flux setpoint
P1596[3] Int. time field weak. controller
P1610[3] Continuous torque boost (SLVC)
P1611[3] Acc. torque boost (SLVC)
P1654[3] Smooth time for Isq setpoint
P1715[3] Gain current controller
P1717[3] Integral time current controller
P1745[3] Variance flux error
P1750[3] Control word of motor model
P1755[3] Start-freq. motor model (SLVC)
P1756[3] Hyst.-freq. motor model (SLVC)
P1758[3] Chng-ov. del. t SLVC op.-lp ctrl
P1759[3] Chng-ov. del. t SLVC cl.-lp ctrl
P1764[3] Kp of n-adaption (SLVC)
P1767[3] Tn of n-adaption (SLVC)
P1780[3] Control word of Rs/Rr-adaption
P1781[3] Tn of Rs-adaption
P1786[3] Tn of Xm-adaption
P1803[3] Max. modulation
P1820[3] Reverse output phase sequence
P1909[3] Ctrl. word of motor data ident.
P2000[3] Reference frequency
P2001[3] Reference voltage
P2002[3] Reference current
P2003[3] Reference torque
P2004[3] Reference power
P2150[3] Hysteresis frequency f_hys
P2153[3] Time-constant frequency filter
P2155[3] Threshold frequency f_1
P2156[3] Delay time of threshold freq f_1
P2157[3] Threshold frequency f_2
P2158[3] Delay time of threshold freq f_2
P2159[3] Threshold frequency f_3
P2160[3] Delay time of threshold freq f_3
P2161[3] Min. threshold for freq. setp.
P2162[3] Hysteresis freq. for overfreq.
P2163[3] Entry freq. for perm. deviation
P2164[3] Hysteresis frequency deviation
P2165[3] Delay time permitted deviation
P2166[3] Delay time ramp up completed
P2167[3] Switch-off frequency f_off
P2168[3] Delay time T_off
ParNo Parameter text
P2170[3] Threshold current I_thresh
P2171[3] Delay time current
P2172[3] Threshold DC-link voltage
P2173[3] Delay time DC-link voltage
P2174[3] Torque threshold M_thresh
P2176[3] Delay time for torque threshold
P2177[3] Delay time for motor is blocked
P2178[3] Delay time for motor pulled out
P2181[3] Belt failure detection mode
P2182[3] Belt threshold frequency 1
P2183[3] Belt threshold frequency 2
P2184[3] Belt threshold frequency 3
P2185[3] Upper torque threshold 1
P2186[3] Lower torque threshold 1
P2187[3] Upper torque threshold 2
P2188[3] Lower torque threshold 2
P2189[3] Upper torque threshold 3
P2190[3] Lower torque threshold 3
P2192[3] Time delay for belt failure
P2201[3] Fixed PID setpoint 1
P2202[3] Fixed PID setpoint 2
P2203[3] Fixed PID setpoint 3
P2204[3] Fixed PID setpoint 4
P2205[3] Fixed PID setpoint 5
P2206[3] Fixed PID setpoint 6
P2207[3] Fixed PID setpoint 7
P2208[3] Fixed PID setpoint 8
P2209[3] Fixed PID setpoint 9
P2210[3] Fixed PID setpoint 10
P2211[3] Fixed PID setpoint 11
P2212[3] Fixed PID setpoint 12
P2213[3] Fixed PID setpoint 13
P2214[3] Fixed PID setpoint 14
P2215[3] Fixed PID setpoint 15
P2231[3] Setpoint memory of PID-MOP
P2240[3] Setpoint of PID-MOP
P2480[3] Position mode
P2481[3] Gearbox ratio input
P2482[3] Gearbox ratio output
P2484[3] No. of shaft turns = 1 Unit
P2487[3] Positional error trim value
P2488[3] Distance / No. of revolutions