Issue 01/06 Parameters
MICROMASTER 440 Parameter List
6SE6400-5BB00-0BP0
23
2.7 Connector Output Parameters
ParNo Parameter text
r0020 CO: Freq. setpoint before RFG
r0021 CO: Act. filtered frequency
r0024 CO: Act. filtered output freq.
r0025 CO: Act. filtered output voltage
r0026 CO: Act. filtered DC-link volt.
r0027 CO: Act. filtered output current
r0029 CO: Flux gen. current
r0030 CO: Torque gen. current
r0031 CO: Act. filtered torque
r0032 CO: Act. filtered power
r0035[3] CO: Act. motor temperature
r0036 CO:Inverter overload utilization
r0037[5] CO: Inverter temperature [°C]
r0038 CO: Act. power factor
r0039 CO: Energy consumpt. meter [kWh]
r0050 CO: Active command data set
r0051[2] CO: Active drive data set (DDS)
r0061 CO: Act. encoder frequency
r0062 CO: Freq. setpoint
r0063 CO: Act. frequency
r0064 CO: Dev. frequency controller
r0065 CO: Slip frequency
r0066 CO: Act. output frequency
r0067 CO: Act. output current limit
r0068 CO: Output current
r0069[6] CO: Act. phase currents
r0070 CO: Act. DC-link voltage
r0071 CO: Max. output voltage
r0072 CO: Act. output voltage
r0074 CO: Act. modulation
r0075 CO: Current setpoint Isd
r0076 CO: Act. current Isd
r0077 CO: Current setpoint Isq
r0078 CO: Act. current Isq
r0079 CO: Torque setpoint (total)
r0080 CO: Act. torque
r0084 CO: Act. air gap flux
r0086 CO: Act. active current
r0090 CO: Act. rotor angle
r0394 CO: Stator resistance IGBT [%]
ParNo Parameter text
r0395 CO: Total stator resistance [%]
r0396 CO: Act. rotor resistance
r0630[3] CO: Ambient temperature
r0631[3] CO: Stator iron temperature
r0632[3] CO: Stator winding temperature
r0633[3] CO: Rotor winding temperature
r0755[2] CO: Act. ADC after scal. [4000h]
r0947[8] CO: Letzte Fehlermeldung
r0948[12] CO: Fehlerzeit
r0949[8] CO: Fehlerwert
r1024 CO: Act. fixed frequency
r1050 CO: Act. Output freq. of the MOP
r1078 CO: Total frequency setpoint
r1079 CO: Selected frequency setpoint
r1114 CO: Freq. setp. after dir. ctrl.
r1119 CO: Freq. setpoint before RFG
r1170 CO: Frequency setpoint after RFG
r1242 CO: Switch-on level of Vdc-max
r1246[3] CO:Switch-on level kin buffering
r1315 CO: Total boost voltage
r1337 CO: V/f slip frequency
r1343 CO: Imax controller freq. output
r1344 CO: Imax controller volt. output
r1438 CO: Freq. setpoint to controller
r1445 CO: Act. filtered frequency
r1482 CO: Integral output of n-ctrl.
r1490 CO: Droop frequency
r1508 CO: Torque setpoint
r1515 CO: Additional torque setpoint
r1518 CO: Acceleration torque
P1520[3] CO: Upper torque limit
P1521[3] CO: Lower torque limit
r1526 CO: Upper torque limitation
r1527 CO: Lower torque limitation
r1536 CO: Max. trq. motoring current
r1537 CO: Max trq regenerative current
r1538 CO: Upper torque limit (total)
r1539 CO: Lower torque limit (total)
P1570[3] CO: Fixed value flux setpoint
r1583 CO: Flux setpoint (smoothed)