Parameters
12.11 Communication (P740 - P799)
BW500 and BW500/L
Operating Instructions, 12/2016, A5E33482052-AD
187
12.11
Communication (P740 - P799)
Note
Changes to these parameters are not effected until the power to the unit is turned off and
then back on.
These parameters cover the various communications formats supported by the BW500 and
BW500/L: serial printer, Dolphin Plus, SmartLinx, and Modbus.
12.11.1
P742 Word Order Parameter
Note
This parameter affects SmartLinx and Modbus communications
This value determines the format of all unsigned, double-register integers (UINT32),
except for
those in the direct parameter access.
Values
Description
0
f
most significant byte (MSB) is given first
1
least significant byte (LSB) is given first
12.11.2
P750 P769 SmartLinx Module Specific Parameters
These parameters are specific to the SmartLinx module installed. Refer to the module
documentation for a list and description of the specific parameter requirements.
12.11.3
P770 P789 Local Port Parameters
These parameters are specific to programming of the BW500 and BW500/L communication
ports. Refer to Communications (Page 125) for a listing and description of these parameters.
12.12
SmartLinx Hardware Testing
These parameters are used to test and debug a SmartLinx card (if installed).