BW500 and BW500/L
Operating Instructions, 12/2016, A5E33482052-AD
17
• AC version
100 ... 240 V AC +/- 10%, 50/60 Hz, 55 VA max.
Fuse FU3 = 2AG, 2AMP, 250V Slo Blo
• DC version
10 - 30 V DC, 26 W max.
Fuse FU2 = 3.75A Resettable (not user replaceable)
• Compatible with Siemens belt scales or equivalent 1,
2, 4, or 6 load cell scales (1 or 2 load cell scales for
BW500/L)
• Compatible with LVDT equipped scales, with use of
optional interface board
• Location
Indoor/outdoor
• Altitude
2000 m max.
• Ambient temperature
-20 to 50 °C (-5 to 122 °F)
• Relative humidity
Suitable for outdoor (Type 4X / NEMA 4X /IP65 enclosure)
• Installation category
II
• Pollution degree
4
• Type
Type 4X / NEMA 4X / IP65
• Dimensions
285 mm W x 209 mm H x 92 mm D
(11.2" W x 8.2" H x 3.6" D)
• Material
Polycarbonate
Via local keypad and/or Dolphin Plus interface
Illuminated 5 x 7 dot matrix liquid crystal display with 2
lines of 40 characters each
• Program and parameters stored in non-volatile FLASH
ROM, upgradable via Dolphin Plus interface
• Runtime totalizers and clock settings
1)
stored in battery
backed RAM, battery P/N PBD-20200035 or use
equivalent 3V Lithium battery (BR 2335), 5 year life