Parameters
12.13 Test and Diagnostic (P900 - P951)
BW500 and BW500/L
190 Operating Instructions, 12/2016, A5E33482052-AD
Tests the mA output value for the output selected, outputs 1 to 3 (P911 -01 to -03)
1)
Displays the value from the previous measurement. A test value can be entered and the
displayed value is transmitted to the output. Upon returning to the
mode, the parameter
assumes the actual mA output level (
f
= 0).
Use the
and
arrow to scroll the value
1)
BW500/L has one output only
Displays the current mA input value for the input selected, inputs 1 to 2 (P914 – 01 to -02).
Not applicable if mA I/O board is not connected.
Not available for BW500/L
P918 Speed Input Frequency
Displays the frequency of the speed input signal in Hertz.
1 = Total 1
2 = Total 2
3 = Verification Total
4 = Material Test Load
5 = Batch Total
6 = NTEP Total
7 = 0Cal Start Total
8 = 0Cal End Total