Appendix
A.2 Appendix II
BW500 and BW500/L
200 Operating Instructions, 12/2016, A5E33482052-AD
Span
a zero must be done prior
belt must be empty
test weight or chain must be applied
conveyor running at normal speed test reference (chain or weight applied)
moisture input not used
inclination will be used if feature is activated
PID Systems
zero and span criteria must be met
set controller (P400) to manual and adjust the output for 100% belt speed (using the 4 and 8
keys).
If the PID is not set to manual, the speed output will be the last value prior to starting the zero
or span calibration
shut off the prefeed to conveyor
In process where a prefeed device is included, it must be turned off to ensure that no material
is fed onto the belt.
A.2
Appendix II
Appendix II: Software Revision History
Software Revision
Date
Changes
2.00 April 30, 1999
Original software release
2.01 July 20, 1999
French language added
38400 baud rate option
removed
Span updated to reference
current zero value
NTEP printout added
Totalizer rollover updated to
1,000,000 for all resolutions
Added units to verification
totalizer printout
Error display updated to
toggle between error and run
mode