Loading...
Installation
5.4 Interconnection
BW500 and BW500/L
Operating Instructions, 12/2016, A5E33482052-AD
31
Note
Colo
r code for load cells used on Siemens weighfeeders may be different than shown.
Please refer to the weighfeeder wiring diagram.
Where separation between the BW500 and BW500/L and belt scale exceeds 150 m (500 ft.), or
legal for trade certification:
1. remove jumpers from BW500 and BW500/L terminal 11/12 and 13/14.
2. run additional conductors from:
BW500 and BW500/L terminal 12 to scale 'red'
BW500 and BW500/L terminal 13 to scale 'blk'
If the load cell wiring colors vary from those shown, or if extra wires are provided, consult
Siemens.