Installation
5.4 Interconnection
BW500 and BW500/L
34 Operating Instructions, 12/2016, A5E33482052-AD
5.4.6
Scale - LVDT
Siemens Milltronics LVDT Conditioner
Load cell excitation
Siemens Milltronics BW500 and BW500/L
Load cell inputs
Maximum cable run LVDT to Conditioner 300 m (1000 ft)
Belt scale with LVDT
The LVDT Conditioner Card can be mounted on the BW500 or BW500/L Motherboard, or in a
remotely located enclosure. The above wiring diagram is for a remote mounted installation.
† For LVDT Conditioner cards that are mounted on the BW500 or BW500/L Motherboard, use 5
individual wires instead of the 4-conductor shielded cable shown above.