Start Up
6.3 Initial Start Up
BW500 and BW500/L
52 Operating Instructions, 12/2016, A5E33482052-AD
6.3.1
Power Up
Upon initial power up, BW500 and BW500/L displays:
P001 Language
1-En 2-Fr 3-De 4-Es 5-It 6-Po 7-RU
V
1
The initial display prompts the user to select the preferred language.
6.3.2
Programming
Press:
BW500 and BW500/L then scrolls sequentially through the start up program as parameters P001
through P017 are addressed.
P002 Test Reference Selection
Select 1-Weight, 2-Chain, 3-Ecal
V
1
For example: Accept ’weight’ (supplied with scale) as the test reference.
Press the following key:
P003 Number of Load Cells
Enter Number of Load Cells
V
2
For example: accept ’2’ as the number of load cells.
Note
For six load cell belt scales, select 4.
Press the following key:
P004 Rate Measurement System
Select 1-Imperial, 2-Metric
V
2
For example: Accept ’2’ for measurements in metric.

Table of Contents