EasyManua.ls Logo

Siemens Milltronics BW500/L - Belt Speed Compensation

Siemens Milltronics BW500/L
220 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
BW500 and BW500/L
Operating Instructions, 12/2016, A5E33482052-AD
67
Recalibration
7
7.1
Belt Speed Compensation
To achieve optimum accuracy in the rate computation, the belt speed displayed must equal that
of the actual belt speed. As the speeds are likely to differ, a belt speed compensation should be
performed.
Run the conveyor with the belt empty.
View the belt speed.
7.1.1
Access P018
P018 Speed Adjust
Enter New Speed
V
0.60
For example: current speed of 0.6 m/s
Stop the conveyor and measure a length of the belt; marking the forward end (start time) and the
back end (stop time). Use the belt scale as the stationary reference.
Run the belt and measure the time for the belt length to pass over the scale.
speed = (belt length / time) m/s or ft/min.
Refer to the Start Up (Page 47) section for instructions on parameter selection and changing
values.
Press the following key:
P018 Speed Adjust
Enter New Speed
E
0.60
For example: current speed of 0.6 m/s and enter correct speed of 0.63 m/s.
Press the following keys in a sequence:

Table of Contents