Loading...
Recalibration
7.5 Online Calibration
BW500 and BW500/L
86 Operating Instructions, 12/2016, A5E33482052-AD
Press the following key:
P355 Online Calibration Feature
Select: 0-Off, 1-On
E
0
EDIT mode: value can be changed.
Select the Online Calibration feature:
Press the following keys:
7.5.1
Online Calibration feature
Access
P355 Online Calibration Features
Select: 0-Off, 1-On
V
1
Value is accepted.
Enter the weigh bin reference weight, (the amount of material the bin holds between the high
and low levels), in units selected in P005.
Press the following keys in a sequence:
Access
P356 Online Calibration Features
Select: 0-Off, 1-On
V
10.000
For example: reference bin weight.
Enter the max., high, and low limit setpoints as a percentage in P357.
Press the following keys:
P357-01 Online Calibration Limits
MAX Limit:
V
90.0
Limit as a percentage