Connectable components
9.3 PP 72/48D 2/2A PN
NCU 7x0.3 PN
Manual, 09/2011, 6FC5397-1EP40-0BA0
125
1 2 3 4 5 6 7 8 9 10 Default device name
on on on off off off off off pp72x48pn7
off on on off off off off off pp72x48pn6
on off on off off off off off pp72x48pn5
off off on off off off off off pp72x48pn4
on on off off off off off off pp72x48pn3
off on off off off off off off pp72x48pn2
on off off off off off off off pp72x48pn1
off off off off off off off off pp72x48pn
NOTICE
A newly set PROFINET address will only come into effect after power OFF/ON.
9.3.4.4 X111, X222 and X333 digital inputs/outputs
Cable specification
● Connectors: 50-pin ribbon cable connectors
50-pin insulation displacement connectors with cable grip, ribbon cables and terminal
converters
are required for connecting digital inputs and outputs.
● The required connecting cables (ribbon cables) must be provided by the user
.
● Max. cable length: 30 m