inbetriebnahme.fm
A31003-S2000-M102-2-76A9, 28/05/2009
OpenScape Voice - OpenStage Family, Administration Manual
2-13
Startup
Quick Start
Example dhcpd.conf
# General configuration for all clients in the subnet
subnet 192.168.2.0 netmask 255.255.255.0 {
option domain-name-servers 192.168.2.2;
option broadcast-address 192.168.2.255;
option routers 192.168.2.251;
option subnet-mask 255.255.255.0;
option domain-name "phones.intranet";
option ntp-servers 192.43.244.18;
option time-offset 3600;
default-lease-time 864000;
max-lease-time 8640000;
}
# Set up an option space to contain the vendor-encapsulated options
option space OpenStage;
option OpenStage.vendor code 1 = string;
option OpenStage.vlanid code 2 = unsigned integer 32;
option OpenStage.dls code 3 = string;
# Each vendor-class-identifier will constitute a class
class "vendor-classes" {
match option vendor-class-identifier;
}
# Specifications for OpenStage phones
subclass "vendor-classes" "OptiIpPhone" {
vendor-option-space OpenStage;
option OpenStage.vendor "Siemens";
option OpenStage.vlanid 4;
option OpenStage.dls "sdlp://192.168.2.103:18443";
option sip-server 192.168.2.117;
}

Table of Contents

Other manuals for Siemens OpenStage 15

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Siemens OpenStage 15 and is the answer not in the manual?

Siemens OpenStage 15 Specifications

General IconGeneral
TypeIP Phone
ConnectivityEthernet
Power over Ethernet (PoE)Yes
SpeakerphoneYes
KeysFixed function keys
Headset PortYes
ProtocolsSIP
DisplayMonochrome display
AudioG.711, G.729
Power SupplyPoE or external power adapter

Related product manuals