EasyManua.ls Logo

Siemens PERFECT HARMONY GENIII/E Series - Page 74

Siemens PERFECT HARMONY GENIII/E Series
140 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
The Keypad and Display Interface Perfect Harmony GENIII/e User’s Manual
3-38 A1A19000405A: Version 1.3
s
s
ss
3
Table 3-24: Output Processing Menu (3050)
Parameter ID Units Default Min Max Description
Low freq comp 3060 Submenu
Menu contains parameters that effect
motor flux calculation. See Table
3-25.
Flux control 3100 Submenu
This menu contains the flux control
parameters. See Table
3-26.
Speed loop 3200 Submenu
This menu contains the speed loop
parameters. See Table
3-27.
Current loop 3250 Submenu
This menu contains the current loop
parameters. See Table
3-28.
Stator resis est 3300 Submenu
This menu contains the stator
resistance estimator parameters.
See Table 3-29.
Braking 3350 Submenu
This menu contains the dual frequency
braking parameters. See Table
3-30.
PLL prop gain 3420 188.0 1.0 500.0
Proportional gain of output
phase-locked loop.
PLL integral
gain
3430 2760.0 0.0 12000.0
Integral gain of output phase-locked
loop. This value is updated only by the
control.
Output current
scaler
3440 1.0 0.0 2.0 Scaling for output current feedbacks.
Output voltage
scaler
3450 1.0 0.0 2.0 Scaling for output voltage feedbacks

Related product manuals