Table 3-40: Pick list for Analog Variable parameters (all units are %)
Table 3-41: Speed Setpoint Menu (4240)
Motor Voltage Total Current Average Power Analog Input #1
Motor Speed Speed Demand Speed Reference Analog Input #2
Raw Flux Demand Flux Reference Current (RMS) Analog Input #3
Zero Sequence Av Neg Sequence D Neg Sequence Q Analog Input #4
Input Frequency Input Power Avg Input Pwr Factor Analog Input #5
Ah Harmonic Bh Harmonic Total Harmonics Analog Input #6
Xfmr Therm Level 1 Cycle Protect Single Phase Cur Analog Input #7
Under Volt Limit Out Neutral Volts Synch Motor Field Analog Input #8
Motor Torque Encoder Speed
Parameter ID Units Default Min Max Description
Speed setpoint 1 4250 rpm 0 -18000 18000
Programmable speed setpoint
that can be selected through an
external contact and the system
program.
Speed setpoint 2 4260 rpm 0 -18000 18000
Programmable speed setpoint
that can be selected through an
external contact and the system
program.
Speed setpoint 3 4270 rpm 0 -18000 18000
Programmable speed setpoint
that can be selected through an
external contact and the system
program.
Speed setpoint 4 4280 rpm 0 -18000 18000
Programmable speed setpoint
that can be selected through an
external contact and the system
program.
Speed setpoint 5 4290 rpm 0 -18000 18000
Programmable speed setpoint
that can be selected through an
external contact and the system
program.
Speed setpoint 6 4300 rpm 0 -18000 18000
Programmable speed setpoint
that can be selected through an
external contact and the system
program.