Power Modules
4.2 Blocksize Power Modules (PM240-2)
AC Drive
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
109
Table 4- 10 Technical data of the PM240-2, FSC (200 V)
Line voltage 1-phase/3-phase 200 … 240 VAC ± 10%
3-phase 200 … 240 VAC
±10%
Order number
without integrated line filter
with integrated line filter
6SL3210–
1PB21-4UL0
1PB21-4AL0
6SL3210–
1PB21-8UL0
1PB21-8AL0
6SL3211–
1PB21-8UL0
1PB21-8AL0
6SL3210–
1PC22-2UL0
1PC22-2AL0
6SL3210–
1PC22-8UL0
1PC22-8AL0
Rated current I
n
Base-load current I
H
for S6 operation (40%) l
s6
max
A
A
A
13,6
10,4
15,0
17,5
13,6
19,3
17,5
13,6
19,3
22,0
17,5
24,2
28,0
22,0
30,8
1)
based on I
n
kW
kW
3,0
2,2
4,0
3,0
4,0
3,0
5,5
4,0
7,5
5,5
4)
3
2)
with/without integrated line reactor
A 35,9 43,0 43,0 29,0 37,0
Rated current
Short-circuit current rating
A
50
60
60
40
50
3NE 1817-0
3NE 1818-0
3NE 1818-0
3NE 1802-0
3NE 1817-0
of the external
Ω ≥ 75 ≥ 75 ≥ 37 ≥ 20 ≥ 20
Max. cable length
to braking resistor
Line supply connection L1, L2, PE
Screw-type terminals
cable cross-section: 6 … 16 mm
2
Tightening torque: 1.3 Nm
Motor connection U2, V2, W2
DC-link connection, connection for
braking resistor
DCP/R1, DCN, R2