Power Modules
4.2 Blocksize Power Modules (PM240-2)
AC Drive
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
115
Table 4- 14 Technical data of the PM240-2, FSC (400 V)
Line voltage 3-phase 380 … 480 VAC ± 10%
Order number
without integrated line filter
with internal line filter
6SL3210–
1PE22-7UL0
1PE22-7AL0
6SL3210–
1PE23-3UL0
1PE23-3AL0
6SL3211–
1PE23-3UL0
1PE23-3AL0
Rated current I
n
Base-load current I
H
for S6 operation (40%) l
s6
max
A
A
A
26,0
18,0
28,6
32,0
26,0
37,1
32,0
26,0
37,1
1)
based on I
n
kW
kW
11,0
7,5
15,0
11,0
15,0
11,0
4)
3
2)
with/without integrated line reactor
A 32,6 39,9 39,9
Rated current
Short-circuit current rating
A
50
50
50
3NE 1817-0
3NE 1817-0
3NE 1817-0
of the external
Ω ≥ 30 ≥ 30 ≥ 30
Max. cable length
to braking resistor
L1, L2, L3,
Screw-type terminals
cable cross-section: 6 … 16 mm
2
Tightening torque: 1.3 Nm
Motor connection U2, V2, W2
DC-link connection, connection for
braking resistor
DCP/R1, DCN, R2