EasyManua.ls Logo

Siemens S120 - Page 115

Siemens S120
500 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Power Modules
4.2 Blocksize Power Modules (PM240-2)
AC Drive
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
115
Table 4- 14 Technical data of the PM240-2, FSC (400 V)
Line voltage 3-phase 380480 VAC ± 10%
Internal
Push-through
Order number
without integrated line filter
with internal line filter
6SL3210
1PE22-7UL0
1PE22-7AL0
6SL3210
1PE23-3UL0
1PE23-3AL0
6SL3211
1PE23-3UL0
1PE23-3AL0
Output current
Rated current I
n
Base-load current I
H
for S6 operation (40%) l
s6
Peak current l
max
A
A
A
A
26,0
18,0
28,6
39,0
32,0
26,0
37,1
52,0
32,0
26,0
37,1
52,0
Type rating
1)
based on I
n
based on I
H
kW
kW
11,0
7,5
15,0
11,0
15,0
11,0
Rated pulse frequency
kHz
4
4
4
Power loss
kW
0,3
0,37
0,37
4)
Cooling air requirement
m
3
/s
0,0185
0,0185
0,0185
24 VDC supply
for the Control Unit
A
1,0
1,0
1,0
Rated input current
2)
with/without integrated line reactor
A 32,6 39,9 39,9
Class J UL fuses
Rated current
Short-circuit current rating
SCCR
A
kA
50
65
50
65
50
65
NH fuses
IEC 60947
Rated current
A
3NE 1817-0
50
3NE 1817-0
50
3NE 1817-0
50
Resistance value
of the external
braking resistor
Ω ≥ 30 ≥ 30 ≥ 30
Max. cable length
to braking resistor
m
15
15
15
Line supply connection
L1, L2, L3,
PE
Screw-type terminals
cable cross-section: 6 … 16 mm
2
Tightening torque: 1.3 Nm
Motor connection U2, V2, W2
DC-link connection, connection for
braking resistor
DCP/R1, DCN, R2

Table of Contents

Other manuals for Siemens S120

Related product manuals