Power Modules
4.4 Power Modules Chassis
AC Drive
Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
177
Table 4- 42 Maximum output frequencies achieved by increasing the pulse frequency in SERVO
mode
Pulse frequency [kHz]
Maximum output frequency [Hz]
2
300
4
300 / 650
1)
1)
The maximum output frequency of 650 Hz is can only be achieved for a current controller clock
cycle of 125 µs (factory setting: 250 µs.) This is only possible for Power Modules with order
numbers 6SL33101TExxxAA3 and firmware version as of V4.3x.
It is not permissible that the Power Module is operated with its maximum rated current at
output frequencies below 10 Hz. Otherwise, its service life could be reduced.