EasyManua.ls Logo

Siemens S120 - Technical Data

Siemens S120
500 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Motor-side power components
6.2 Chassis
AC Drive
246 Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
6.2.3.7
Technical data
Table 6- 25 Technical data, dV/dt filter plus Voltage Peak Limiter
Order number
6SL3000-
2DE32-6AA0
2DE35-0AA0
Suitable for Power Module (unit
rating)
6SL3310- 1TE32-1AAx (110 kW)
1TE32-6AAx (132 kW)
1TE33-1AAx (160 kW)
1TE33-8AAx (200 kW)
1TE35-0AAx (250 kW)
I
thmax
A
260
490
Degree of protection
IP00
IP00
dV/dt reactor
Power loss
- at 50 Hz
- at 60 Hz
- at 150 Hz
kW
kW
kW
0,701
0,729
0,78
0,874
0,904
0,963
Connections
- to the Power Module
- load
- PE
M10
M10
M6
M12
M12
M6
Max. permissible
cable length between dV/dt
reactor and motor
m 300 (shielded)
450 (unshielded)
Dimensions
Width
Height
Depth
mm
mm
mm
410
370
229
460
370
275
Weight, approx.
kg
66
122
Voltage Peak Limiter
Power loss
- at 50 Hz
- at 60 Hz
- at 150 Hz
kW
kW
kW
0,029
0,027
0,025
0,042
0,039
0,036
Connections
- to the dV/dt reactor
- DC
- PE
M8
M8
M8
Terminal 70 mm²
Terminal 70 mm²
Terminal 35 mm²
Dimensions
Width
Height
Depth
mm
mm
mm
265
263
190
392
285
210
Weight, approx.
kg
6
16