Cabinet design and EMC for components, Blocksize format
10.5 24 V DC Supply Voltage
AC Drive
426 Manual, (GH6), 04/2014, 6SL3097-4AL00-0BP4
Selecting power supply units
You are advised to use the devices in the following table. These devices meet the applicable
requirements of EN 60204-1.
Table 10- 4 Recommended SITOP Power
Rated input voltage [V]
Operating voltage range [V]
Short-circuit current [A]
5 1 / 2 AC 120 … 230 / 230 … 500
85 … 264 / 176 … 550
Approx. 5.5 (power up)
Typ. 15 for 25 ms
6EP1333-3BA00-8AC0
10 1 / 2 AC 120 … 230 / 230 … 500
85 … 264 / 176 … 550
Approx. 12 (power up)
Typ. 30 for 25 ms
6EP1334-3BA00-8AB0
20 1 / 2 AC 120 / 230
Approx. 23 (power up)
Typ. 60 for 25 ms
(operation)
6EP1336-3BA00-8AA0
3 3 AC 230 / 400 … 288 / 500
6EP1436-3BA00-8AA0
40 1 / 2 AC 120 / 230
Approx. 46 (power up)
Typ. 120 for 25 ms
(operation)
6EP1337-3BA00-8AA0
3 3 AC 230 / 400 … 288 / 500
6EP1437-3BA00-8AA0
Table 10- 5 Recommendation for Control Supply Module
Short-circuit current [A]
20 3 380 V 3 AC -10 % (-15 % < 1
min) to 480 V 3 AC +10%
DC 300 … 800
< 24 6SL3100-1DE22-0AAx
Refer also to Catalog PM21 or NC61.
Danger to life through a hazardous voltage when connecting an unsuitable power supply
Touching live components can result in death or severe injury.
• Connect the ground potential to the protective conductor connection.
• Mount the power supply close to the drive lineup.
Ideally, they should be mounted on a common mounting plate. If different mounting
plates are used, their electrical interconnection must comply with the EMC installation