Approvals
SIMATIC CM 1242-5
Operating Instructions, 01/2023, C79000-G8976-C245-06
47
ATEX / IECEx / UKEX / CCC-Ex
Observe the information in the "Use of subassemblies/modules in a Zone 2 Hazardous Area"
document, which you will find here:
• On the documentation DVD supplied with the product, under:
"All documents" >"Use of subassemblies/modules in a Zone 2 Hazardous Area"
• On the Internet at the following address:
Link: (https://support.industry.siemens.com/cs/ww/en/view/78381013)
The conditions must be met for safe usage of the product according to the section Notes on
use in hazardous areas according to ATEX / UKEX / IECEx / CCC-Ex (Page 17).
The product meets the explosion protection requirements outlined below.
Observe installation guidelines
The product meets the requirements if you observe the following during installation and
operation:
• The notes in the section Important notes on using the device (Page 17)
• The installation instructions in the document /1/ (Page 51)
IECEx
Classification: Ex ec IIC T4 Gc, Certificate no.: IECEx DEK 18.0019X
The product meets the requirements of the standards:
• IEC 60079-0 - Explosive atmospheres - Part 0: Equipment - General requirements
• IEC 60079-7 - Explosive Atmospheres - Part 7: Equipment protection by increased safety 'e'
ATEX
Classification: II 3 G Ex ec IIC T4 Gc, Certificate no.:DEKRA 18ATEX0027 X
The product meets the requirements of the standards:
• EN IEC 60079-0 - Explosive atmospheres - Part 0: Equipment - General requirements
• EN 60079-7 - Explosive Atmospheres - Part 7: Equipment protection by increased safety 'e'
UKEX
Classification: II 3 G Ex ec IIC T4 Gc, Certificate no.:DEKRA 21UKEX0003 X
The product meets the requirements of the standards:
• EN IEC 60079-0 - Explosive atmospheres - Part 0: Equipment - General requirements
• EN 60079-7 - Explosive Atmospheres - Part 7: Equipment protection by increased safety 'e'
Importer UK: Siemens plc (see above)
CCC-Ex
Classification:Ex na IIC T4 Gc (not on the type plate), Certificate no.:2020322310002625