EasyManua.ls Logo

Siemens S7-1200 - Configuration of the TeleService access

Siemens S7-1200
1028 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
STEP 7 programming software
2.3 Easy-to-use tools
S7-1200 Programmable controller
System Manual, 03/2014, A5E02486680-AG
45
2.3.10
Changing the call type for a DB
STEP
7 allows you to easily create or change the
association o
f a DB for an instruction or an FB that is in
an FB.
You can switch the association between different DBs.
You can switch the association between a single-
instance DB and a multi-instance DB.
You can create an instance DB (if an instance DB is
missing or not available).
You can access the "Change call type" command either
by right
-clicking the instruction or FB in the program
editor or by selecting the "Block call" command from the
"Options" menu.
The "Call options" dialog allows
you to select a single
-instance
or multi
-instance DB. You can
also select specific DBs from a
drop
-down list of available DBs.

Table of Contents

Other manuals for Siemens S7-1200

Related product manuals