Communication
10.2 PROFINET
S7-1200 Programmable controller
System Manual, 03/2014, A5E02486680-AG
517
As shown in the following example, you can also use individual TSEND and TRCV
instruction to communication over a connection created by a TSEND_C or TRCV_C
instruction. The TSEND and TRCV instructions do not themselves create a new connection,
so must use the DB and connection ID that was created by a TSEND_C, TRCV_C or TCON
instruction.
①
TSEND_C on CPU_1 creates a
connection and assigns a connection
ID to that connection (ID=1).
TRCV_C on CPU_2 creates a
connection and assigns the
connection ID to that connectio
n on
③
TSEND and TRCV on CPU_1 use the
connection ID created by the
TSEND_C on CPU_1 (ID=1).
TSEND and TRCV on CPU_2 use the
connection ID created by the TRCV_C
on CPU_2 (ID=1).
Configuring the Local/Partner connection path (Page 150)
The integrated PROFINET port of the CPU supports multiple communications standards
over an Ethernet network:
● Transport Control Protocol (TCP)
● ISO on TCP (RFC 1006)
● User Datagram Protocol (UDP)