Technical specifications
A.8 Analog signal modules (SMs)
S7-1200 Programmable controller
910 System Manual, 03/2014, A5E02486680-AG
Table A- 144 Connector pin locations for SM 1231 AI 4 x 16 bit (6ES7 231-5ND30-0XB0)
Note
Unused voltage input channels should be shorted.
Unused curent input channels should be set to the 0 to 20 mA range and/or disable broken
wire error reporting.
Inputs configured for current mode will not conduct loop current un
less the module is
Current input channels will not operate unless external power is supplied to the transmitter.
SM 1232 analog output module specifications
Table A- 145 General specifications
Dimensions W x H x D (mm)
Current consumption (SM Bus)
Current consumption (24 VDC)
Table A- 146 Analog outputs
Range ±10 V, 0 to 20 mA, or 4 mA to 20
±10 V, 0 to 20 mA, or 4 mA to 20
Resolution Voltage: 14 bits
Voltage: 14 bits