Programming the program blocks
5.4 IF_CONF: SDT for the configuration data of the CP
CP 1243-7 LTE
100 Operating Instructions, 01/2015, C79000-G8976-C381-01
Header of IF_CONF
Table 5- 1 IF_CONF_Header
Byte
Parameter
Data type
Initial value
Description
0 ... 1
fieldType
UINT
Field type: Must always be 0.
2 ... 3 fieldId UINT Field ID: Must always be 0.
4 ... 5
subfieldCnt
UINT
Total number of fields contained in the structure
General parameters of the parameter fields
Each field has the following general parameters:
Id
This parameter identifies the field and must not be modified.
Length
This parameter indicates the length of the field. The value serves as information.
Fields with strings and / or arrays have a variable length. Due to hidden bytes, the actual
length of fields can be greater than the sum of the displayed parameters.
Mode
The following values are permitted to these parameters:
Table 5- 2 Values of "Mode"
Value
Meaning
1 Permanent validity of the configuration data
Not relevant for the CP
2 Temporary validity of the configuration data, including deleting of existing permanent
configuration data
The permanent configuration data is replaced by the parameter fields of IF_CONF.