Micro Automation Set 14 Entry ID 21062588
V2.0 05/18/05 18/35
Copyright © Siemens AG 2005 All rights reserved
Set14_DocTech_V2.0_en.doc
5.3 Configuring components
Configuring configuration PC
Table 5-2
No. Function Comment
1.
To ensure the functionality of Micro
Automation Set 14, the following software
must be installed depending on the
configuration.
• STEP 7-Micro/WIN
• STEP 7 V5.3
2.
The following network settings have to be
applied on the used network card of the
PC:
• IP address: 192.168.2.141
• Subnet mask: 255.255.255.0
Configuring S7-200 “Basis” with MicroWin project
Table 5-3
No. Function Comment
1.
Connect the S7-200 CPU to a DC 24V
power supply.
2.
Connect the configuration PC and S7-200
“Basis” with a USB/PPI cable via the
USB interface of the PC.
3.
Plug the ribbon cable of CP 243-1 in the
interface at the S7-200 CPU.
4.
Plug the clock cartridge in the S7-200
CPU.
S7-200 CPU 222
Clock
Configuration PC
PPI cable
S7-200 “Basis”