Web diagnostics
11.3 Diagnostics pages of the CP
Configuring and commissioning S7 CPs for Industrial Ethernet
180 Configuration Manual, 09/2013, C79000-G8976-C182-13
Parameters
Function
Mode Displays the current network properties (transmission speed and direction). Possible values:
10 Mbps half duplex
10 Mbps full duplex
100 Mbps half duplex
100 Mbps full duplex
1 Gbps full duplex
Mode when using media redundancy (for details, refer to "media redundancy" navigation)
Media redundancy Display of the role and with the manager, the ring status:
Manager: Ring closed
Manager: Ring open
Client
"Statistics" tab
This page provides information about the number of sent or received frames since the
module was last restarted.
On CPs with integrated switches, the frames sent or received by the CP are displayed under
"Interface". In addition to this, the frames that only pass through the switch are displayed
under "Port number...".
Parameters
Function
Data packets sent
CP interface: X2 Total number of frames sent error-free via all ports of the CP. These also include
unicast, multicast and broadcast frames and frames aborted due to collisions.
Port number: X2P1...X2Pn Number of frames sent error-free via the port. These also include unicast, multicast and
broadcast frames and frames aborted due to collisions.
In addition to the CP interface, the frames generated directly by the port or forwarded
due to the switch function are also recorded.
Received data packets
CP interface: X2 Total number of frames received error-free via all ports. These also include:
Unicast, multicast and broadcast frames
Frames denied due to checksum or alignment errors
Frames denied due to lack of resources
Port number: X2P1...X2Pn Number of frames received error-free via the port. These also include:
Unicast, multicast and broadcast frames
Frames denied due to checksum or alignment errors
Frames denied due to lack of resources
In addition to the CP interface, the frames that were forwarded by the port due to the
switch function are also recorded.