Connector pinout
A.3 Connector for Industrial Ethernet
Configuring and commissioning S7 CPs for Industrial Ethernet
224 Configuration Manual, 09/2013, C79000-G8976-C182-13
1
P0-P TD+ / RD+
Transmit + / Receive +
3
P1-P TD+ / RD+
Transmit + / Receive +
5
P2-N TD- / RD-
Transmit - / Receive -
7
P3-P TD+ / RD+
Transmit + / Receive +
All four pairs of wires (P0, P1, P2, P3) can be operated with duplex.
Connector for Industrial Ethernet
Connector pinout - 15-pin D-sub female connector
External chassis ground, shield
Transmit + / TPE Transmit Data +
Receive + / TPE Receive Data +
9 CLSN_N Collision -
Transmit - / TPE Transmit Data -
11 Ground 5 V ground
Receive - / TPE Receive Data -
The pin assignment corresponds to the IEEE 802.3 AUI interface.
The signals TPETXD / TPETXD_N and TPERXD / TPERXD_N form the ITP interface.