10.4 Set reference point
FM 352 electronic cam controller
Operating Instructions, 05/2011, A5E01071724-03
111
Effects of the setting
Based on the example "set reference point" to 300 mm, you can see how this setting shifts
the working range of the axis.
This has the following effects:
The actual position is set to the value of the reference point coordinate.
The working range is physically shifted on the axis.
The various points retain their original coordinates, but are now at new physical positions.
The SYNC bit is set in the checkback signals.
Table 10- 4 Shifting the working range on the axis using "Set Reference Point"
Set reference point SLS
[mm]
REF
[mm]
ACT
[mm]
SLE
[mm]
-400
-200
100
400





>PP@
>PP@
$[LV
2IIVHW
RIWKHZRUNLQJ
UDQJHWKURXJK
6HWUHIHUHQFH
SRLQWWRPP
2OGFRRUGLQDWHV\VWHP
1HZFRRUGLQDWHV\VWHP
:RUNLQJbUDQJH
6/6
6/(
$&7
-400
-200
300
400
Special features of absolute encoders
This setting is required for an absolute encoder adjustment (see chapter "Determining the
correct absolute encoder adjustment (Page 82)").