Settings
10.5 Change cam edges
FM 352 electronic cam controller
112 Operating Instructions, 05/2011, A5E01071724-03
10.5 Change cam edges
Definition
The "change cam edges" setting can be used to change the cam start during operation. With
a position-based cam, the cam end of an individual position-based cam can also be changed
during operation.
Requirement
The cam you want to change must be valid.
Sequence of the setting
1. Enter the cam number in the channel DB.
2. For a position-based cam:
Enter the cam start and cam end in the channel DB.
For a time-based cam:
Enter the cam start value in the channel DB.
3. Set the relevant trigger bit.
Data used in the channel DB
Address Name Type Initial value Comment
36.7 CH01CAM_EN BOOL FALSE 1 = write setting for cam edges (1 cam)
102.0 CAM_NO INT 0 Cam number
104.0 CAM_START DINT L#0 Cam start
108.0 CAM_END DINT L#0 Cam end