Data blocks / error lists
C.1 Content of the channel DB
FM 352 electronic cam controller
Operating Instructions, 05/2011, A5E01071724-03
181
Address Name Type Initial value Comment
Done bits for read jobs
43.1 MDRD_D BOOL FALSE 1 = "read machine data" job completed
43.2 CAM1RD_D BOOL FALSE 1 = "read cam data 1" job completed
43.3 CAM2RD_D BOOL FALSE 1 = "read cam data 2" job completed
43.4 CAM3RD_D BOOL FALSE 1 = "read cam data 3" job completed
43.5 CAM4RD_D BOOL FALSE 1 = "read cam data 4" job completed
43.6 CAM5RD_D BOOL FALSE 1 = "read cam data 5" job completed
43.7 CAM6RD_D BOOL FALSE 1 = "read cam data 6" job completed
44.0 CAM7RD_D BOOL FALSE 1 = "read cam data 7" job completed
44.1 CAM8RD_D BOOL FALSE 1 = "read cam data 8" job completed
44.2 MSRRD_D BOOL FALSE 1 = "read measured values" job completed
44.3 CNTTRC_D BOOL FALSE 1 = "read count values of counter cam tracks"
job completed
44.4 ACTPOS_D BOOL FALSE 1 = "read position and track data" job
completed
44.5 ENCVAL_D BOOL FALSE 1 = "read actual encoder value" job completed
44.6 CAMOUT_D BOOL FALSE 1 = "read position and track data" job
completed
Error bits for function switches
46.0 EDGE_ERR BOOL FALSE 1 = error in "Activate edge detection" or
"Deactivate edge detection"
46.1 SIM_ERR BOOL FALSE 1 = error in "Activate simulation" or
"Deactivate simulation"
46.2 MSR_ERR BOOL FALSE 1 = error in "Activate length measurement" or
"Deactivate length measurement"
46.3 REFTR_ERR BOOL FALSE 1 = error in "Activate retrigger reference point"
or "Deactivate retrigger reference point"
46.4 SSW_ERR BOOL FALSE 1 = error in "Activate software limit switch" or
"Deactivate software limit switch"
Error bits for write jobs
47.0 MDWR_ERR BOOL FALSE 1 = error in "Write machine data" job
47.1 MD_ERR BOOL FALSE 1 = error in "activate machine data" job
47.2 AVALREM_ERR BOOL FALSE 1 = error in "Cancel set actual value" or
"Cancel set actual value on-the-fly"
47.3 CAM1WR_ERR BOOL FALSE 1 = error in "Write cam data 1" job
47.4 CAM2WR_ERR BOOL FALSE 1 = error in "Write cam data 2" job
47.5 CAM3WR_ERR BOOL FALSE 1 = error in "Write cam data 3" job
47.6 CAM4WR_ERR BOOL FALSE 1 = error in "Write cam data 4" job
47.7 CAM5WR_ERR BOOL FALSE 1 = error in "Write cam data 5" job

Table of Contents