Data blocks / error lists
C.4 Error classes
FM 352 electronic cam controller
Operating Instructions, 05/2011, A5E01071724-03
193
No. Meaning Diagnostic
interrupt
Incorrect distance/encoder revolution
11
Cause The value for distance/encoder revolution is outside the
permitted range of 1 to 10
9
µm (regardless of the resolution).
Yes
13 Incorrect number of increments/encoder revolution (see chapter "Machine data
of the encoder (Page 86)")
Yes
14 Incorrect number of increments/encoder revolution (see chapter "Machine data
of the encoder (Page 86)")
Yes
Incorrect baud rate 15
Cause You have specified a baud rate outside the permitted range of
0 to 3.
Yes
Incorrect reference point coordinate 16
Cause The coordinate is outside the range of -100 m to +100 m or -
1000 m to +1000 m, depending on the resolution.
Linear axis: The coordinate is outside the operating range.
Rotary axis: The coordinate is < 0 or greater than the end of
rotary axis.
Yes
Incorrect absolute encoder adjustment 17
Cause SSI encoder: The value of the absolute encoder adjustment is
not in the encoder range: [increments per encoder revolution] x
[number of revolutions - 1].
Yes
Incorrect type of reference point retrigger 18
Cause You have specified a value other than 0, 1, 6 and 7.
Yes
Incorrect direction adaptation 19
Cause You have specified a value other than 0 and 1.
Yes
Hardware monitoring not possible 20
Cause You set frame error monitoring = FALSE at the parameter DB.
The monitoring of missing pulses is not possible with the
encoder used. Disable the MON_PULSE parameter.
Yes
Incorrect software limit switch start 21
Cause Linear axis: The software limit switch start is outside the
traversing range
(-100 m to +100 m or -1000 m to +1000 m, depending on the
resolution).
Linear axis: The software limit switch start (including any
existing zero offset) is less than -100 m or -1000 m (depending
on the resolution).
Yes
22 Incorrect software limit switch end Yes
Cause Linear axis: The software limit switch end is outside the
traversing range (-100 m to +100 m or
-1000 m to +1000 m, depending on the resolution) or is less
than the software limit switch start.
The software limit switch end (including any existing zero
offset) is greater than +100 m or +1000 m (depending on the
resolution).