Data blocks / error lists
C.4 Error classes
FM 352 electronic cam controller
198 Operating Instructions, 05/2011, A5E01071724-03
No. Meaning Diagnostic
interrupt
Absolute encoder frame error
Cause The frame traffic between FM 352 and the absolute
encoder (SSI) is incorrect or interrupted:
Encoder cable cut or not plugged in
Incorrect encoder type
Encoder incorrectly set (programmable encoders)
Frame length incorrectly specified
Encoder returns incorrect values (encoder defective)
Interference on measuring system cable
Selected baud rate is too high
Effect
Cam processing will be deactivated
Track outputs will be disabled
The last correct actual value remains unchanged until
the end of the next correct SSI transfer
145
Remedy
Check the encoder cable
Check the encoder
Check the frame traffic between the encoder and
FM 352
Yes
Missing pulses of incremental encoder
Cause
Encoder monitoring has detected missing pulses
Number of increments per encoder revolution is
incorrectly entered
Encoder defective: does not return the defined
number of pulses
Bad or missing zero marker
Interference on the encoder cable
Effect
Cam processing will be deactivated
Track outputs will be disabled
Synchronization is canceled
146
Remedy
Enter the correct number of increments/encoder
revolution
Check the encoder and its cable
Comply with shielding and grounding regulations
Monitoring can be temporarily disabled using the
parameter assignment interface, but at the
responsibility of the operator.
Yes