Machine and cam data
9.6 Physical units system
FM 352 electronic cam controller
Operating Instructions, 05/2011, A5E01071724-03
73
9.6 Physical units system
Selecting a system of units
You can choose a specific system of units for the input and output of data in the parameter
assignment interface of the cam controller (default: mm).
You can set any of the following as the system of units:
● mm, inches, degrees, and pulse.
Note
If you change the system of units in the parameter assignment interface under STEP 7,
the values are converted to the new system. This may lead to rounding errors.
Values are not converted automatically if you change the system of units via the machine
data.
If the system of units is changed from or to "pulses", the cam processing is deactivated,
and the axis is no longer synchronized.
System of units in the parameter DB
Address Name Type Initial value Comment
8.0 UNITS DINT L#1 System of units
1 = 10
-3
mm
2 = 10
-4
inch
3 = 10
-4
degrees
4 = 10
-2
degrees
5 = pulses
6 = 10
-3
degrees