EasyManua.ls Logo

Siemens S7-300 - Example: Adjusting the Absolute Encoder

Siemens S7-300
226 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Machine and cam data
9.9 Example: Adjusting the absolute encoder
FM 352 electronic cam controller
84 Operating Instructions, 05/2011, A5E01071724-03
9.9 Example: Adjusting the absolute encoder
Assumptions
For this example, let us presume:
Reference point coordinate = -125 mm
Working range of SSW_STRT = - 1000 mm to SSW_END = 1000 mm
Absolute encoder adjustment = 0
Encoder range = 2048 increments (= pulses) at a resolution of 1 mm/pulse
A precise mechanical adjustment of the absolute encoder is not possible, and there is no
option for setting a selective actual value.

 



 



&XUUHQW
$[LV
$[LV
9DOXHRIDEVROXWHHQFRGHU
(QFRGHU
$FWXDOYDOXH
(QFRGHUYDOXH
'HVLUHG
(1) Assignment of the coordinate system to encoder values, based on the absolute encoder
adjustment. Encoder value 0 is equivalent to actual value -125.
(2) Required assignment of the coordinate system to the encoder. The coordinate value
should be -125 at this position.