Connecting up
4.6 Fitting the IE FC TP standard cable 4 x 2 GP to an IE IP 67 hybrid connector
SCALANCE W788-xPRO/RR / SCALANCE W74x-1PRO/RR
Operating Instructions (Compact), Release 08/2007, A5E00413342-05
101
Contact 6
(Blue)
Contact 1
(Yellow)
Contact 2
(Orange)
Contact 3
(White)
Contact and color assignment of the splice element.
Color coding of the standard cable White /
orange
*
Orange White /
green
*
Green
Connector color code (Siemens IE) White Blue Yellow Orange
Siemens IE FC RJ-45 socket (reference) 3 6 1 2
*
White wire of the pair.
Insert the all the data leads at the same time into the
splice element is far as they will go.
Close the splice element and RJ-45 data module until
they lock together.
Insert the data module and the splice element into the
supplied IDC assembly tool.