Technical Specifications   
7.1 Technical specifications 
  SCALANCE X-200 
100  Compact Operating Instructions, 12/2010, A5E00813159-11 
Table 7- 7  Permitted cable lengths (fiber-optic) 
Device type 
SCALANCE 
1 - 50 m 
980/1000 plastic 
optical fiber (POF) 
1 - 100 m 
200/230 polymer cladded 
fiber (PCF) 
6 dB max. permitted FO 
cable attenuation with 3 dB 
link power margin 
0 - 4000 m 
Glass FO cable 50/125 µm 
glass fiber; 
 
0 - 5000 m 
Glass FO cable 62.5/125 µm 
glass fiber; 
 
≤ 1 dB/km at 1300 nm;  
600 MHz x km;  
6 dB max. permitted FO 
cable attenuation with 3 dB 
link power margin 
0 - 26000 m 
glass FOC 
10/125 µm single mode fiber; 0.5 
dB/km at 1300 nm; 
13 dB max. permitted FO cable 
attenuation with 2 dB link power 
margin 
XF204 - -  -  - 
X208 - -  -  - 
XF208 - -  -  - 
X216 - -  -  - 
X224 - -  -  - 
X204-2 - -  +  - 
XF204-2 -  -  +  - 
X206-1 - -  +  - 
XF206-1 -  -  +  - 
X212-2 - -  +  - 
X204-2LD -  -  -  + 
X206-1LD -  -  -  + 
X212-2LD -  -  -  + 
X202-2IRT -  -  +  - 
X204IRT -  -  -  - 
XF204IRT -  -  -  - 
X204 IRT PRO  -  -  -  - 
X202-2P IRT PRO  +  +  -  - 
X201-3P IRT PRO  +  +  -  - 
X202-2P IRT +  +  -  - 
X201-3P IRT +  +  -  - 
X200-4P IRT +  +  -  - 
 
Table 7- 8  MTBF 
Device type 
SCALANCE 
Degree of protection  MTBF 
XF204  IP20  48.03 years 
X208  IP30  83.71 years 
XF208  IP20  54.80 years 
X216  IP30  52.07 years 
X224  IP30  45.87 years 
X204-2  IP30  74.64 years 
XF204-2  IP20  43.58 years