EasyManua.ls Logo

Siemens SCALANCE XF208 - Page 94

Siemens SCALANCE XF208
110 pages
Go to English
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Certifications and approvals
6.1 Notes on the CE Mark
SCALANCE X-200
94 Compact Operating Instructions, 12/2010, A5E00813159-11
Device type
SCALANCE
IEC 60068-2-6 vibration IEC 60068-2-27 shock
X201-3P IRT 5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 11 ms duration
6 shocks per axis
X200-4P IRT 5 – 9 Hz: 3.5 mm
9 – 500 Hz: 1 g
1 octave/min, 20 sweeps
15 g, 11 ms duration
6 shocks per axis
Note
The interfaces of the X-200 IE switches can be divided into groups each with 4 ports:
P1 to P4
P5 to P8
P9 to P12
etc.
If only ports of different port groups are used, the device meets the requirements for
Environment B in compliance with IEEE 802.3, Section 33.4.1.1. If ports of the same port
group are used, the requirements for Environment A are met.