Description
2
2.1 Performance features
The PAC2200 is a measuring device for measuring the basic electrical variables in low-
voltage power distribution. All measured variables are shown on the display of the PAC2200.
The device is capable of single-phase, two-phase, or three-phase measurement and can be
used in TN and TT networks.
The PAC2200 is mounted on a DIN rail.
The PAC2200 measuring device is available in several versions:
5 A device:
X / 1 A and x / 5 A current transformers can be used for current measuring.
65 A device:
No current transformers are required for current measuring. The device is connected directly
to the low-voltage network. Current of up to 65 A can be measured directly.
Depending on the device version, the PAC2200 measuring device has an integrated
Ethernet, RS485 or M-BUS interface.
Thanks to its large measuring voltage range, the PAC2200 measuring device can be
connected directly in any low-voltage system up to a voltage UL-L 480 V.
Measurement
Measurement of all relevant electrical variables in an AC system
Acquisition of the minimum and maximum values of all measured variables.
Averaging of all measured values directly on the device in two stages, which are
independent of each other and freely configurable (aggregation)
Counters and average power demand values
Recording of active, reactive and apparent energy by means of several energy counters
Calculation and storage of the average demand in the last measuring period for active
power and reactive power for simple generation of load profiles using software
(programmable measurement period of between 1 and 60 min)

Table of Contents