A.1 Measured variables
SENTRON PAC4200
Manual, 09/2008, A5E02316180B-01
193
Name Abbrev.
DE + IEC
Abbrev.
EN + NAFTA
Unit Displ
ay
LIM
SOURCE
Minimum sliding window demand reactive power a
(VAR1)
VAR
1 a sw-dmd
min
VAR
1 a sw-dmd min
VAR 6.5
Minimum value of the sliding window demand of the reactive power of the fundamental in phase
conductor a, measured according to VAR1
Sliding window demand reactive power b (VAR1) VAR
1 b sw-dmd
VAR
1 b sw-dmd
VAR 6.3 VAR1 DMD b
Sliding window demand of the reactive power of the fundamental in phase conductor b referred to the
load counting system, measured according to VAR1
Maximum sliding window demand reactive power b
(VAR1)
VAR
1 b sw-dmd
max
VAR
1 b sw-dmd max
VAR 6.4
Maximum value of the sliding window demand of the reactive power of the fundamental in phase
conductor b, measured according to VAR1
Minimum sliding window demand reactive power b
(VAR1)
VAR
1 b sw-dmd
min
VAR
1 b sw-dmd min
VAR 6.5
Minimum value of the sliding window demand of the reactive power of the fundamental in phase
conductor b, measured according to VAR1
Sliding window demand reactive power c (VAR1) Q
1 L3 sw-dmd
VAR
1 c sw-dmd
VAR 6.3 VAR1 DMD c
Sliding window demand of the reactive power of the fundamental in phase conductor c referred to the
load counting system, measured according to VAR1
Maximum sliding window demand reactive power c
(VAR1)
VAR
1 c sw-dmd
max
VAR
1 c sw-dmd max
VAR 6.4
Maximum value of the sliding window demand of the reactive power of the fundamental in phase
conductor c, measured according to VAR1
Minimum sliding window demand reactive power c
(VAR1)
VAR
1 c sw-dmd
min
VAR
1 c sw-dmd min
VAR 6.5
Minimum value of the sliding window demand of the reactive power of the fundamental in phase
conductor c, measured according to VAR1
Sliding Window Demand Total Apparent Power S
sw-dmd
VA
sw-dmd
VA 7.3 ΣVA DMD
Sliding window demand of the total apparent power
Maximum sliding window demand total apparent
power
S
sw-dmd max
VA
sw-dmd max
VA 7.4
Maximum sliding window demand of the total apparent power
Minimum sliding window demand total apparent power S
sw-dmd min
VA
sw-dmd min
VA 7.5
Minimum sliding window demand of the total apparent power
Sliding Window Demand Total Active Power P
sw-dmd
W
sw-dmd
W 7.3 ΣW DMD
Sliding window demand of the total active power
Maximum sliding window demand total active power P
sw-dmd max
W
sw-dmd max
W 7.4
Maximum sliding window demand of the total active power
Minimum sliding window demand total active power P
sw-dmd min
W
sw-dmd min
W 7.5
Minimum sliding window demand of the total active power