7 Operation at Use of a PC
7.3 Configuration of the Device
156 SICAM P850/P855, 7KG85xx, Device Manual
E50417-H1040-C482-A6, Edition 10.2018
✧ In the navigation window of the Recording and Reporting menu click Recording parameters.
Figure 7-47 Configure Tab, Recording Parameters Input/Output Window (Excerpt)
✧ Select the parameter in the list box according to Table 7-18.
✧ After the parameterization click Send.
The parameters are transmitted to the device but not enabled yet (passive set of parameters).
✧ If you do not want to make any additional settings, continue with the Activation of the device configuration
according to section Activating the Set of Parameters. If you want to change other settings, enter the
changes and then enable the device configuration as described in section Activating the Set of
Parameters.
Depending on the parameterized Start record option, the Start time field shows the start time of the recording.
After activation, the recording starts automatically at the specified time. If the Start immediately option is
selected, the recording also only starts after activation.
After recording has started, the Recording status fields shows the entry Running.
✧ If you want to stop the recording, click on Stop recording and execute the activation.
The Recording status field shows the entry Not running and Start recording is displayed on the user
interface.
NOTE
The restart of the record is carried out after a power failure automatically.
The status will change from Not running to Running when user change and activate parameters.