7 Operation at Use of a PC
7.4 Value View and Evaluation
176 SICAM P850/P855, 7KG85xx, Device Manual
E50417-H1040-C482-A6, Edition 10.2018
7.4 Value View and Evaluation
7.4.1 Process Connections and Automation Functions
The values for Operational parameters (Process connections and Automation functions) are displayed in
the Value view and Evaluation tab. To display the values on the screen, proceed as follows:
Select the Value view and Evaluation tab on the user interface.
Figure 7-57 Value View and Evaluation Tab
In the navigation window, open the Operational menu, then the Process connections or Automation
functions submenu and click one of the following items:
AC operational values
Harmonics voltage
Harmonics current
AC power and energy
Flicker (Only SICAM P855)
Binary outputs
Measurand limits
Group indications
Depending on which operational parameters are selected, the input/output window displays the measured
values of the measurands with the corresponding unit or indications in a tabular list that is updated
every 5 s. Harmonics can represent you in tabular form or graphically.
NOTE
The operational measured values cos (a) to cos (c) and cos as well as UIa to UIc and UI are
additionally marked with "i" for inductive or "c" for capacitive in the table.

Table of Contents