9 Operation at Use of a PC
9.3 Configuration of the Device
192 SICAM Q100, 7KG95xx, Device Manual
E50417-H1040-C522-A6, Edition 06.2019
9.3.6 Recording and Reporting
In the Configure tab, you can view and, if necessary, edit the settings for recording and reports. You can select
these parameters in the Recording and reporting menu in the navigation window. The menu contains the fol-
lowing elements:
Event recorder
Trigger management
Recorder parameters
Mains signaling voltage
Memory management
Report configuration
Recording parameters
Transient detection
9.3.6.1 Event Recorder
Default Settings and Setting Ranges
Table 9-14 Event Recorder
Parameter Default Setting Setting Range
Voltage event
Swell threshold 110 % 105 % to 140 % in 5-% steps
Dip threshold 90 % 75 % to 95 % in 5-% steps
Interruption threshold 5 % 1 %, 2 %, 3 %, 5 %, 8 % 10 %
Hysteresis 2 % 1 % to 6 % in 1-% steps
Event detection mode
1)
ph-N ph-N
ph-ph
RVC event
RVC threshold 6 % 1 % to 6 % in 1-% steps
RVC hysteresis
2)
3 % 0.5 % to 3 % in 0.5-% steps
RVC event detection mode
3)
ph-N ph-N
ph-ph
Frequency event
Underfrequency threshold 1 % 0.1 % to 1.0 % in 0.1-% steps and
1.0 % to 5.0 % in 1.0-%-steps
MAN_SICAM_Q100_US.book Page 192 Wednesday, June 5, 2019 9:31 AM